EMI effects of cathodic protection on electromagnetic flowmeters


Creative Commons License

Gündoğdu S., Sahin Ö.

SENSORS, vol.7, no.1, pp.75-83, 2007 (SCI-Expanded) identifier identifier

  • Publication Type: Article / Article
  • Volume: 7 Issue: 1
  • Publication Date: 2007
  • Doi Number: 10.3390/s7010075
  • Journal Name: SENSORS
  • Journal Indexes: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Page Numbers: pp.75-83
  • Keywords: corrosion, cathodic protection methods, electromagnetic flowmeter (EMF), electromagnetic interference (EMI)
  • Dokuz Eylül University Affiliated: Yes

Abstract

Electromagnetic flowmeters are used to measure the speed of water flow in water distribution systems. Corrosion problem in metal pipelines can be solved by cathodic protection methods. This paper presents a research on corruptive effects of the cathodic protection system on electromagnetic flowmeter depending on its measuring principle. Experimental measurements are realized on the water distribution pipelines of the Izmir Municipality, Department of Water and Drainage Administration (IZSU) in Turkey and measurement results are given. Experimental results proved that the values measured by the electromagnetic flowmeter (EMF) are affected by cathodic protection system current. Comments on the measurement results are made and precautions to be taken are proposed.