Numerical analysis of a near-room-temperature magnetic cooling system


EZAN M. A., EKREN O., Metin C., YILANCI A., BIYIK E., Kara S. M.

INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, cilt.75, ss.262-275, 2017 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 75
  • Basım Tarihi: 2017
  • Doi Numarası: 10.1016/j.ijrefrig.2016.12.018
  • Dergi Adı: INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.262-275
  • Anahtar Kelimeler: Magnetic cooling, Computational fluid dynamics, ANSYS-FLUENT, User defined functions, THERMODYNAMIC CYCLES, HEAT-EXCHANGERS, REGENERATOR, REFRIGERATOR, SIMULATION, DESIGN, MODEL
  • Dokuz Eylül Üniversitesi Adresli: Evet

Özet

In this study, for a near-room-temperature magnetic cooling system, a decoupled multiphysics numerical approach (Magnetism, Fluid Flow, and Heat Transfer) is developed using a commercial CFD solver, ANSYS-FLUENT, as a design tool. User defined functions are incorporated into the software in order to take into account the magnetocaloric effect. Magnetic flux density is assumed to be linear during the magnetization and demagnetization processes. Furthermore, the minimum and maximum magnetic flux densities (B-min and B-max) are defined as 0.27 and 0.98, respectively. Two different sets of analyses are conducted by assuming an insulated cold heat exchanger (CHEX) and by defining an artificial cooling load in the CHEX. As a validation case, experimental work from the literature is reproduced numerically, and the results show that the current methodology is fairly accurate. Moreover, parametric analyses are conducted to investigate the effect of the velocity of heat transfer fluid (HTF) and types of HTF on the performance of the magnetic cooling system. Also, the performance metrics of the magnetic cooling system are investigated with regards to the temperature span of the magnetic cooling unit, and the cooling load. It is concluded that reducing the cycle duration ensures reaching lower temperature values. Similarly, reducing the velocity of the HTF allows reducing the outlet temperature of the HTF. In the current system, the highest temperature spans are obtained numerically as around 6 K, 5.2 K and 4.1 K for the cycle durations of 4.2 s, 6.2 s and 8.2 s, respectively. (C) 2016 Elsevier Ltd and IIR. All rights reserved.