Optimum Screw Configuration for the Fixation of Sanders Type IIC Tongue-Type Fractures? A Biomechanical Study


Bacaksiz T., KAZIMOĞLU C., Reisoglu A., Turgut A., Kumtepe E., Agus H.

JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, cilt.108, sa.1, ss.20-26, 2018 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 108 Sayı: 1
  • Basım Tarihi: 2018
  • Doi Numarası: 10.7547/16-140
  • Dergi Adı: JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.20-26
  • Dokuz Eylül Üniversitesi Adresli: Evet

Özet

Background: The minimally invasive technique (percutaneous screw fixation) is one of the options for treating tongue-type IIC fractures successfully. The aim of this study was to assess the biomechanics of four different screw configurations used for the fixation of tongue-type IIC calcaneal fractures.