Evaluation of the Effects of Repeated Insertion-Removal Cycles on the Retention of an Indexed Conometric Connection


Tuna S. H., Al-Chalabi Z. S., Kozak E.

INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, cilt.37, sa.3, ss.549-555, 2022 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 37 Sayı: 3
  • Basım Tarihi: 2022
  • Doi Numarası: 10.11607/jomi.9497
  • Dergi Adı: INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, CINAHL, EMBASE, MEDLINE, DIALNET
  • Sayfa Sayıları: ss.549-555
  • Anahtar Kelimeler: conometric concept, double crown, insertion-removal cycle, matrix, patrix, retention, ELECTROPLATED GOLD COPINGS, IN-VITRO INVESTIGATIONS, FIXED PARTIAL DENTURES, ATTACHMENT SYSTEMS, WEAR BEHAVIOR, CEMENT, FORCE, PRECISION, IMPLANTS, TITANIUM
  • Dokuz Eylül Üniversitesi Adresli: Hayır

Özet

Purpose: The objectives of this in vitro study were to evaluate changes in the retention force of the indexed conometric system subjected to repeated insertion-removal cycles and to examine the elements (matrix and patrix) that cause retention changes in the system as a result of repeated cycles. Materials and Methods: Monolithic zirconia crowns were cemented on 24 matrixes and 24 patrixes fixed on the implant analog. The pull-out test was performed with 12 matrixes and 12 patrixes attached, and the initial retention forces were recorded. Six of them were subjected to five insertion-removal cycles (5-cycle group), and the other six samples to 15 cycles (15-cycle group), and the final retention forces were calculated. Then, in both groups, an element of each pair exposed to the cycle was matched by an exchanging with new pieces: 5 cycles of matrix-new patrix (5M/0P), 5 cycles of patrix-new matrix (5P/0M), 15 cycles of matrix-new patrix (15M/0P), and 15 cycles of patrix-new matrix (15P/0M); thus, subgroups were created. A pull-out test was applied to these subgroups, and retention forces were recorded. Data were subjected to a paired-samples t test (alpha = .05). Two specimens from the 15-cycle group were randomly selected and analyzed by scanning electron microscopy. Results: In the 5-cycle group, the mean initial retention force was 153.13 +/- 7.08 N, and the mean final retention force was 111.59 +/- 18.30 N. In the 15-cycle group, the mean initial retention force was 143.30 +/- 15.46 N, and the mean final retention force was 78.55 +/- 17.03 N. There was a statistically significant loss of retention in both groups (P < .05). The change in retention in the 5P/0M and 15P/0M subgroups was not statistically significant (P> .05). However, significant loss of retention was found in the 5M/0P and 15M/0P subgroups (P < .05). Conclusion: There was a significant loss of the retention force after insertion-removal cycles. The increase in these cycles caused a further decrease in retention force. The decrease in the retention force of this system mainly resulted from the changes in the surface characteristic of the frictional surfaces of the matrix.