Co-digestion of mixed industrial sludge with municipal solid wastes in anaerobic simulated landfilling bioreactors


Agdag O. N., SPONZA D. T.

JOURNAL OF HAZARDOUS MATERIALS, cilt.140, ss.75-85, 2007 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 140
  • Basım Tarihi: 2007
  • Doi Numarası: 10.1016/j.jhazmat.2006.06.059
  • Dergi Adı: JOURNAL OF HAZARDOUS MATERIALS
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.75-85
  • Anahtar Kelimeler: municipal solid waste, bioreactor, mixed industrial sludge, co-digestion, simulated anaerobic landfilling bioreactor, SEWAGE-SLUDGE, AZO DYES, LEACHATE, TOXICITY, CODISPOSAL, BIOSOLIDS
  • Dokuz Eylül Üniversitesi Adresli: Evet

Özet

In this study, the feasibility of the anaerobic co-digestion of a mixed industrial sludge with municipal solid wastes (MSW) was investigated in three simulated anaerobic landfilling bioreactors during a 150-day period. All of the reactors were operated with leachate recirculation. One of them was loaded only with MSW (control reactor); the second reactor was loaded with mixed industrial sludge and MSW, the weight ratio of the MSW to mixed industrial sludge was 1:1 (based on dry solid) (Run 1); the third reactor was loaded with mixed industrial sludge and MSW, the weight ratio of the MSW to mixed industrial sludge was 1:2 (based on dry solid) (Run 2). The VFA concentrations decreased significantly in Run 1 and Run 2 reactors at the end of 150 days. The pH values were higher in Run 1 and Run 2 reactors compared to control reactor. The differences between leachate characteristics, the biodegradation and the bioefficiency of the reactors were compared. The NH4-N concentrations released to leachate from mixed sludge in Run 1 and Run 2 reactors were lower than that of control reactor. The BOD5/COD ratios in Run 1 and Run 2 reactors were lower than that of control reactor at the end of 150 days. Cumulative methane gas productions and methane percentages were higher in Run 1 and Run 2 reactors. Reductions in waste quantity, carbon percentage and settlement of the waste were better in Run 1 and Run 2 reactors compared to control reactor at the end of 150 days. Furthermore, TN and TP removals in waste were higher in reactors containing industrial sludge compared to control. The toxicity test results showed that toxicity was observed in reactors containing; industrial mixed sludge. (c) 2006 Elsevier B.V. All rights reserved.