Lesion-Aware Multiple-Instance Learning for Grapevine Disease Recognition from Field RGB Images


ÖZTÜRK Ö., CANBULA B., ÖZACAR ÖZTÜRK T., ÖZACAR V.

Sensors, cilt.26, sa.19, 2026 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 26 Sayı: 19
  • Basım Tarihi: 2026
  • Doi Numarası: 10.3390/s26196318
  • Dergi Adı: Sensors
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Compendex, EMBASE, INSPEC, MEDLINE, Directory of Open Access Journals, Academic Search Ultimate (EBSCO), Biomedical Reference Collection: Corporate Edition (EBSCO), Health Research Premium Collection (ProQuest)
  • Anahtar Kelimeler: ablation study, annotation-guided learning, bootstrap uncertainty, grapevine disease recognition, lesion detection, multiple-instance learning, offline image analysis
  • Dokuz Eylül Üniversitesi Adresli: Evet

Özet

This retrospective offline study examines how dense manual regional annotations can be organized for image-level grapevine disease recognition using pre-acquired HERMOS RGB images. After audit and filtering, 491 source images and 13,765 Pascal VOC regions were retained. A leakage-safe source-image split was used across full-image classification, regional crop classification, crop-to-image aggregation, annotation-guided multiple-instance learning (MIL), and YOLO11 localization. MIL bags in training, validation, and testing were constructed from crops derived from manual boxes; the results therefore describe annotation-assisted aggregation rather than raw-image deployment. The original ConvNeXt-Tiny MIL model achieved macro-F1 0.922 (95% source-image bootstrap CI 0.882–0.956), compared with 0.836 (0.754–0.895) for full-image ConvNeXt-Tiny and 0.869 (0.804–0.917) for the best fixed crop aggregation. Paired macro-F1 differences favored MIL over these baselines by 0.087 (95% CI 0.029–0.163; Holm-adjusted p = 0.013) and 0.053 (0.005–0.114; adjusted p = 0.036), respectively. Downy mildew precision and recall were 1.000 on nine positive test images, but the corresponding exact 95% binomial intervals were 0.664–1.000. Controlled ablations produced lower point estimates without learned attention or the auxiliary instance loss, whereas removing context expansion did not reduce performance; none of the three paired ablation tests was significant after Holm correction. Increasing detector capacity from YOLO11n to YOLO11s did not improve full-image mAP@0.50 (0.175 versus 0.170). These findings support annotation-guided local-evidence aggregation as an offline exploratory benchmark, while not establishing split-to-split stability, computational efficiency, or external-vineyard generalization.