EVALUATION OF THREE DIFFERENT CALCIUM SILICATE-BASED REPAIR MATERIALS IN TERMS OF MICROLEAKAGE: IN VITRO STUDY
ESE Autumn Meeting 2026, Vilniaus, Lithuania, 23 - 24 October 2026, pp.1, (Summary Text)
- Publication Type: Conference Paper / Summary Text
- City: Vilniaus
- Country: Lithuania
- Page Numbers: pp.1
- Dokuz Eylül University Affiliated: Yes
Abstract
EVALUATION OF THREE DIFFERENT CALCIUM
SILICATE-BASED REPAIR MATERIALS IN TERMS OF MICROLEAKAGE: IN VITRO STUDY
Ece Çelikbay, Yağmur Kılıç, Mustafa Mert Tulgar
Aim
To
evaluate and compare the sealing ability of three distinct calcium
silicate-based repair materials—manually mixed Mineral Trioxide Aggregate (MTA
Angelus) and two premixed bioceramic alternatives (Bio-C Repair and TotalFill
BC RRM Fast Set Putty)—in simulated furcation perforation repair using a
spectrophotometric microleakage dye penetration analysis.
Methodology
Sixty
standardized dentin discs (2.5 mm thickness, 1.6 mm perforation diameter)
obtained from extracted human maxillary molars were randomly distributed into
three experimental groups (n=20 per group): Group 1 (MTA Angelus), Group 2
(Bio-C Repair), and Group 3 (TotalFill BC RRM Fast Set Putty). Following
precise material placement and condensation according to standardized protocols
using paper points and hand pluggers, specimens were incubated at 37°C with
100% humidity for 24 hours to allow initial polymerization. Microleakage was
evaluated using a 2% methylene blue dye penetration test for 48 hours.
Subsequently, the specimens were fully dissolved in 65% nitric acid for 48
hours. Quantitative chemical evaluation of dye microleakage was performed by
measuring optical absorbance density at 550 nm using a UV/Vis spectrophotometer
against a reference blank. Normal data distribution was verified using the
Shapiro-Wilk test, and statistical variations among experimental groups were
analyzed using one-way ANOVA followed by Tukey’s post-hoc pairwise comparison
tests at a significance level of p<0.05.
Results
One-way
ANOVA demonstrated statistically significant differences in microleakage values
across all evaluated repair material groups (p<0.001). Manually mixed MTA
Angelus demonstrated the lowest mean optical absorbance density values
(0.255±0.100), indicating a statistically superior sealing ability and
interfacial adaptation compared to the ready-to-use materials. Among the premixed
formulations, TotalFill BC RRM Fast Set Putty exhibited a significantly lower
mean microleakage absorbance (0.543±0.181) compared to Bio-C Repair
(0.725±0.209), which was confirmed as a statistically significant difference by
Tukey’s post-hoc analysis (p=0.003).
Conclusions
Within the
limitations of this in vitro laboratory study, manually mixed MTA Angelus
significantly outperformed the premixed bioceramic alternatives in terms of
sealing performance and resistance to microleakage. The accelerated chemical
setting mechanism and optimized handling characteristics of TotalFill BC RRM
Fast Set Putty may offer superior early stabilization and interfacial
adaptation compared to Bio-C Repair during the initial setting phase. This
study received no external funding or financial support.