Dislocation of capsular bag with intraocular lens and capsular tension ring
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, cilt.32, sa.10, ss.1756-1758, 2006 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 32 Sayı: 10
- Basım Tarihi: 2006
- Doi Numarası: 10.1016/j.jcrs.2006.05.016
- Dergi Adı: JOURNAL OF CATARACT AND REFRACTIVE SURGERY
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
- Sayfa Sayıları: ss.1756-1758
- Dokuz Eylül Üniversitesi Adresli: Evet
Özet
We report a case in which the capsular bag with an intraocular lens (IOL) and a capsular tension ring (CTR) dislocated into the vitreous. The dislocated foldable posterior chamber IOL and CTR were removed with a pars plana vitrectomy and exchanged with a scleral-fixated IOL. No complications occurred intraoperatively or postoperatively. Although insertion of a CTR decreases the risk for IOL dislocation, spontaneous capsular bag dehiscence can occur. (c) 2006 ASCRS and ESCRS.