Quantitative Synthesis of CO<sub>2</sub>Fixation Rates and Indoor Air Pollutant Removal by Microalgae: A Systematic Review and Meta-Analysis
INDOOR AIR, cilt.2026, sa.1, 2026 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 2026 Sayı: 1
- Basım Tarihi: 2026
- Doi Numarası: 10.1155/ina/1291972
- Dergi Adı: INDOOR AIR
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Compendex, Environment Index, Academic Search Ultimate (EBSCO), Natural Science Collection (ProQuest), Biomedical Reference Collection: Corporate Edition (EBSCO), Health Research Premium Collection (ProQuest)
- Dokuz Eylül Üniversitesi Adresli: Evet
Özet
Poor indoor air quality (IAQ) is linked to premature deaths, respiratory diseases, reduced cognitive function, increased energy costs, and diminished well-being. Although traditional air filtration and ventilation systems are common, microalgae-based systems are emerging as a sustainable alternative. This systematic review and meta-analysis provide pooled quantitative estimates of microalgae CO2 fixation rates for IAQ applications. In accordance with PRISMA guidelines, 46 studies from the Web of Science and Scopus databases were included in the qualitative synthesis. Thirteen comparisons reporting quantitative CO2 fixation rates were analyzed using a random-effects meta-analysis with DerSimonian-Laird method and publication bias assessment through a funnel plot and Egger ' s regression test. To the authors ' knowledge, this is the first meta-analysis of microalgae CO2 fixation rates for IAQ application providing pooled estimates and evaluating pollutant removal efficiency, microalgae species, and building integration strategies. The pooled CO2 fixation rate was 99.77 mg/L/day (95% CI: 80.09-119.46), with rates ranging from 90.59 mg/L/day for Spirulina sp. to 156.70 mg/L/day for Scenedesmus sp. For building-integrated applications, the ambient subgroup estimate of 35.09 mg/L/day (95% CI 26.43-43.75) is the recommended design benchmark, although experiments under optimized laboratory conditions achieve removal rates of 80%-99% CO2, up to 100% volatile organic compounds (VOCs), 55.42%-98% of particulate matter (PM2.5) and 66%-95% of carbon monoxide (CO), nitrogen monoxide (NO), and nitrogen dioxide (NO2). Although the variability among studies limits broader applicability, these findings enable informed system sizing and species selection criteria for building applications. Pilot-scale and standardized research is essential for advancing these technologies. This review is registered with OSF and supported by the Research Fund of Dokuz Eylul University.