Determination of UV Filters in Surface Water by VA-DLLME-SFOD Technique Coupled with GC-MS/MS


Yücel C., Ertaş H., Ertaş F. N., Karapınar İ.

CLEAN-SOIL AIR WATER, cilt.50, sa.8, 2022 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 50 Sayı: 8
  • Basım Tarihi: 2022
  • Doi Numarası: 10.1002/clen.202100246
  • Dergi Adı: CLEAN-SOIL AIR WATER
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Aqualine, Aquatic Science & Fisheries Abstracts (ASFA), BIOSIS, Biotechnology Research Abstracts, CAB Abstracts, Chemical Abstracts Core, Environment Index, Geobase, Greenfile, INSPEC, Pollution Abstracts, Veterinary Science Database
  • Anahtar Kelimeler: central composite face-centered design, river water, solidified floating organic droplet, UV filters, vortex-assisted dispersive liquid-liquid microextraction, injector port derivatization, LIQUID-LIQUID MICROEXTRACTION, FLOATING ORGANIC DROPLET, CHROMATOGRAPHY-MASS SPECTROMETRY, SOLID-PHASE EXTRACTION, GAS-CHROMATOGRAPHY, ULTRAVIOLET-FILTERS, IONIC LIQUID, RAPID-DETERMINATION, SENSITIVE DETERMINATION, SWIMMING POOL
  • Dokuz Eylül Üniversitesi Adresli: Evet

Özet

A simple, rapid, and sensitive method is developed for the determination of UV filters in river waters by applying the vortex-assisted dispersive liquid-liquid microextraction based on solidified floating organic droplet technique followed by the injector port silylation (IPS) in a gas chromatography-tandem mass spectrometry system. Statistical experimental design methods including general factorial design, one factor at a time, and central composite face-centered design are used for optimization purposes. Under optimized conditions, 460 mu L of acetone and 30 mu L of 2-dodecanone are rapidly injected into a 10 mL water sample with 10% (w/v) NaCl at pH 2.5 and vortexed for 3 min. After centrifugation, 2 mu L of the separated organic solvent is subjected to auto-IPS with 1 mu L of bis (trimethylsilyl) trifluoroacetamide containing 1% trimethylchlorosilane, at 260 degrees C for 4.5 min in programmable temperature vaporization mode. As a result of the validation studies, the intra-day and inter-day precision indicated as relative standard deviation are less than 12.4% and 18.8%, respectively. For all UV filters, detection limits are between 1.1 and 5.5 ng L-1 and limit of quantitation values are between 3.1 and 16.6 ng L-1. Successful recovery of extraction values (77.1%-107.4%) and good enrichment factors (231-350) are obtained.